Sanitaryware test machine
LEAKtec
Vacuum and siphon leak tests on WCs. Detects leaks as small as 60 microns.
LEAKtec: technical highlights
Test types
Vacuum leakage test and siphon test on WCs.
Defect detection
Micro-leaks, porosity and cracks in the ceramic, down to 60 microns.
Live vacuum reading
The value in bar is shown on screen with a colour status bar, so a pass or a drift is visible at a glance.
Real-time graph
A vacuum-versus-time curve plots every test as it runs.
Adjustable test parameters
Test time, the vacuum threshold to reach (start test pressure) and the maximum vacuum loss tolerated.
Sealing kit
A conical expansion plug on a reinforced flexible hose draws air from the drain duct, and shaped blind plugs in several sizes seal the water inlet and the bowl or siphon opening.
Protective work surface
A two-layer cushion (rigid base, black foam rubber on top) protects the ceramic and gives an airtight seal when the piece is placed on it.
Integrated air unit
Filter and pressure regulator with a 0 to 16 bar gauge, rated for up to 16 bar (1.6 MPa) inlet pressure and 50 °C operating temperature.
Compact bench
Metal profile frame with an open lower compartment that stores hoses and plugs.
Simple controls
A main rotary selector and a double front push-button panel next to the LEAKtec software on the display.